✨ New Arrivals Just Dropped!Explore
Product image 1
HomeStore

Hanna Instruments Electrode Cleaner, 230 mL

Hanna Instruments Electrode Cleaner, 230 mL

The Hanna Instruments Electrode Cleaner is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061M cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.

  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

$16.00
Hanna Instruments Electrode Cleaner, 230 mL
$16.00

Product Information

Shipping & Returns

Description

The Hanna Instruments Electrode Cleaner is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061M cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.

  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

You may also like

Thumbnail 1Thumbnail 2

Agrowtek GrowControl SXHM Hydroponics Sensor Kit With Temp, pH, EC & ORP Probes

$1,072.24

Thumbnail 1Thumbnail 2

Agrowtek pH Probe

$94.33

Thumbnail 1Thumbnail 2

Agrowtek Temperature Probe

$52.54

Thumbnail 1Thumbnail 2

Agrowtek Electrical Conductivity Probe

$142.09

Thumbnail 1Thumbnail 2

RCYAGO Dissolved Oxygen Meter with Electrode Filling Fluid

$142.84

Thumbnail 1

Agrowtek Oxidation Reduction Potential (ORP) Probe

$273.44

-70%
Thumbnail 1Thumbnail 2

Agrowtek SXL Liquid Sensor Mount Flange Kit, for Mounting 1" PVC Pipe

$78.81

$23.64

Thumbnail 1Thumbnail 2

Agrowtek GrowControl SXHM Hydroponics Sensor Kit With Temp, pH, & EC Probes

$834.63

-70%
Thumbnail 1Thumbnail 2

Agrowtek SXL Liquid Sensor Mount System Cap Kit, Tapped Cap & 1" PVC Fitting With Flange Kit

$93.14

$27.94

Thumbnail 1Thumbnail 2

Agrowtek GrowControl PHX Transmitter & Controller With pH & Temperature Sensors

$595.83

Thumbnail 1Thumbnail 2

Agrowtek GrowControl PHX Transmitter & Controller With pH, Temperature & ORP Sensors

$858.51

Thumbnail 1Thumbnail 2

Agrowtek SXL Liquid Sensor Mount System Cap Kit, Tapped Cap & 1" PVC Fitting

$21.50