Milwaukee SE220 Double Junction pH Probe
The SE220 probe is designed for use with the Milwaukee MW101 and MW102 PRO pH Meters.
The SE220 probe makes pH testing easy and requires very little maintenance. Top features include:
Double Junction
The double junction design reduces risk of clogging.
Gel filled
Using a gel removes the need to maintain the electrolyte levels.
Resin body
The ULTEM resin body is highly durable, chemically resistant and protects against accidental damage, good for lab and general purpose applications. ULTEM while generally resistant, may not perform well in highly concentrated or strong alkaline environments.
Care and Use
Properly maintaining your pH probe will give you fast, accurate results for longer.
Here are our top four tips.
- 1. Always store with the cap full of buffer or storage solution not water.
- 2. Clean your probe regularly by soaking in cleaning solution.
- 3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH probe sensor.
- 4. Gently stir the probe in the sample for a faster result.
Specifications for Milwaukee MW600 PRO
| Body: | ULTEM Resin |
|---|---|
| Reference: | Double, Ag/AgCl |
| Junction: | Cloth, single |
| Electrolyte: | Gel |
| Range: | 0-14 pH |
| Tip Shape: | Sphere |
| Diameter: | 0.5 inches |
| Dimensions: | 4.7 inches / 6.4 inches |
| Operating Temperature: | -5 to 70°C (23 to 158°F) |
| MAX Pressure: | 2 BAR |
| Cable Length: | 3.3 feet |
| Connection: | BNC |
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The SE220 probe is designed for use with the Milwaukee MW101 and MW102 PRO pH Meters.
The SE220 probe makes pH testing easy and requires very little maintenance. Top features include:
Double Junction
The double junction design reduces risk of clogging.
Gel filled
Using a gel removes the need to maintain the electrolyte levels.
Resin body
The ULTEM resin body is highly durable, chemically resistant and protects against accidental damage, good for lab and general purpose applications. ULTEM while generally resistant, may not perform well in highly concentrated or strong alkaline environments.
Care and Use
Properly maintaining your pH probe will give you fast, accurate results for longer.
Here are our top four tips.
- 1. Always store with the cap full of buffer or storage solution not water.
- 2. Clean your probe regularly by soaking in cleaning solution.
- 3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH probe sensor.
- 4. Gently stir the probe in the sample for a faster result.
Specifications for Milwaukee MW600 PRO
| Body: | ULTEM Resin |
|---|---|
| Reference: | Double, Ag/AgCl |
| Junction: | Cloth, single |
| Electrolyte: | Gel |
| Range: | 0-14 pH |
| Tip Shape: | Sphere |
| Diameter: | 0.5 inches |
| Dimensions: | 4.7 inches / 6.4 inches |
| Operating Temperature: | -5 to 70°C (23 to 158°F) |
| MAX Pressure: | 2 BAR |
| Cable Length: | 3.3 feet |
| Connection: | BNC |